RADIATION DOSE OPTIMISATION FOR PEDIATRIC BRAIN COMPUTED TOMOGRAPHY IN SELECTED HOSPITALS IN SOUTH-WEST NIGERIA
DOI:
https://doi.org/10.65360/ajemates.v18i1.1000Keywords:
pediatric CT, brain CT, radiation dose, optimization, CTDIvol, DLP, NigeriaAbstract
Background: Computed tomography (CT) provides invaluable high-resolution cross-sectional neuroimaging during pediatric emergencies, but it utilizes ionizing radiation. In many developing nations, a lack of clinical standardization and an absence of localized guidance mean pediatric patients are frequently exposed to uncalibrated adult-derived scanning protocols, resulting in unnecessary stochastic health risks. Aim: To evaluate whether the targeted optimization of pediatric brain CT protocol parameters effectively minimizes radiation doses in ordinary hospital settings in South-West Nigeria. Methods: A quasi-experimental pre-post study was conducted at Obafemi Awolowo University Teaching Hospitals Complex and Biket Medical Centre. The study involved a cohort of 485 pediatric patients aged 0–18 years, comparing 158 retrospective pre-optimization baseline examinations with 327 prospective post-optimization scans. The intervention actively revised protocol parameters including reducing tube voltage {kVp} and tube current-time product {mAs}, increasing pitch, and strictly narrowing scan length boundaries. Primary outcomes were evaluated using independent t-tests to measure shifts in {CTDI vol} and {DLP} (p < 0.05). Results: The participant demographics showed a higher prevalence of males (59.4%) and a dominant adolescent subpopulation (42.7% aged 13–18 years), highlighting trauma-related imaging trends. Following protocol optimization, independent t-tests confirmed massive, statistically significant exposure declines (p < 0.001$). Mean {CTDIvol} plummeted by 67%, dropping from 69.22 mGy before optimization to 23.13 mGy after optimization, representing an approximate 67% reduction. Mean DLP decreased from 1589.61 mGy-cm to 602.70 mGy-cm, representing an approximate 62% reduction.Narrow post-intervention standard deviations demonstrated high, institutional adherence to the newly optimized guidelines. Conclusion: Redesigning scanning protocols and standardizing pediatric-specific parameters yields substantial radiation dose reductions in low-resource clinical environments. This evidence dismantles the assumption that dose reduction is exclusively dependent on premium, expensive hardware upgrades. Nigerian radiology departments and regulatory frameworks should actively adopt child-specific protocols, enforce routine dose auditing, and develop localized pediatric diagnostic reference levels to promote safety.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 African Journal of Educational Management, Teaching and Entrepreneurship Studies

This work is licensed under a Creative Commons Attribution 4.0 International License.